Products

Handheld Scanners


Product Information

Model: NLS-HR1550-3E
Product Category: Cordless 1D Bar Code Scanner
Data type: 1D,Support PDF417 & MircoPDF417
Reading Mode:
Linear Imager
Interface: RS232/USB
Wireless: Zigbee


Overview
NLS-HR1550-3E 1D hand-held bar code scanner is the cordless model of HR15 series, which is also able to read PDF417 and MicroPDF417 stacked 2D bar code. This model adopts Zigbee technology to realize wireless communication and supports standard RS-232 / USB. With good performance, this rugged scanner is very suitable for applications in supermarkets, shopping malls and warehouse environment application, etc.

Features

Data Acquisition

Support common 1D bar codes and PDF417 and MicroPDF417 stacked 2D bar code.


Zigbee Wireless

Zigbee technology, supporting long-distance communication up to 50m & easy networking to expand coverage.


Operating Modes

Data Transmission support Synchronous, Asynchronous and Batch mode. Offline Scanning up to 4095 EAN bar codes of 13mil.


Super One Pair

Cradle and scanner(s) can be paired one-to-one or one-to-many simply via the Match key on cradle. And the cradle is also able to seek the paired scanner(s) via the Match key.



Specification

Performance

Light Source

620nm Visible Red LED

Scan Pattern

CCD linear image

Symbologies

Code128, EAN-13, EAN-8, Code39,UPC-A, UPC-E, Codabar, Interleaved 2 of 5, ISBN, Code 93, UCC/EAN-128, GS1 Databar, PDF417, MicroPDF417 etc.
(Cordless model reading PDF417/MicroPDF417data length is less than 255 bytes)

Resolution

≥ 4mil

Scan Angle

44°

Reading Angle

44°

Scan Rate

300 scans per second

Minimum Symbol Contrast

20%

Interface

RS-232, USB 1.1, PS2(Optional)

Mechanical

Dimensions of Scanner(L x W x H)

113.5 x 73 x 159 mm

Dimensions of Cradle(L x W x H)

195 x 82.5 x 47 mm

Weight of Cordless Scanner

210 g (Including battery)

Weight of Cradle

150g

Reminder

Beep and LED indicator

Power Adaptor

Output: DC5V, ≥1.5A,Input: AC 100~240V, 50~60Hz

Environmental

 

Operation Temperature

-10°C to 50°C (14°F to 122°F)

Storage Temperature

-20°C to 60°C (-4°F to 140°F)

Humidity

5% ~ 95% (Non-condensing)

Static Discharge

±12KV (Air discharge), ±8KV (Direct discharge)

Sealing

IP54

Wireless

Operating Modes

Synchronous, Asynchronous and Batchmode

Radio Technology

2.4 to 2.4835 GHz (ISM Band) frequency - Zigbee communication technology

Communication Range

≥ 50 m

Data Rate

20-250 KBps

Battery

2200mAh Li-ion Battery

Expected Hours of Operation

17 hours

Charging Time

Around 3.5 hours for full charge

Number of Scan

60,000 scans per charge

Certificates

FCC Part15 Class B, CE EMC Class B, CCC

*Specifications are subject to change without notice*



  Document Name Size Document Type
1 NLS-HR1550-3E Datasheet 323 KB Datasheet
2 NLS-HR1550-3E Quick Start 4.78 MB Quick Start
3 NLS-HR1550-3E User Guide 2.92 MB User Guide


1. How to confirm the types of your equipment, X+? X? or other type?
A. X+ type(EM2027 series, last number of serial number is "X+"), supported interface types: USB-DataPipe, USB Com Port Emuation, HID-KBW,RS232.
X type(EM2100 series,last number of serial Number is "X"), supported interface types: USB-DataPipe, USB Com Port Emuation, HID-KBW,RS232.

2. How to confirm whether the driver has been installed successfully?
A. First, confirm the equipment had connected to PC and the equipment operating normally.
Open: Control Panel> Device Manager> Universal Serial Bus Controller,
 If there is "Newland USB Datapipe to series Device" said connection is "USB Com Port Emuation"--COM.
 If there is "Newland USB DataPipe Device" said connection is "USB-DataPipe".
 If there is yellow "!" before the equipment, delete the equipment, and then scan detection hardware changes,  Wait for the system to automatically install the new drivers finished.

3. Whether it is necessary upgrade the driver of USB-Datapipe from the old version to the new v1.2 USB driver (vcomctrl v1.2.exe)?
A. The new driver support USB Interface of X+ : USB-DataPipe/ USB Com Port Emuation/HID-KBW. If the users of X series, had developed their own application through the USB SDK, recommendations are not updated to the latest driver.

4. If you have installed v1.2 USB driver, how to connect by USB-Datapipe?
A. If your equipment is X+ series, read the set code of USB-Datapipe.(You can download The Manual of Settings Code free from this website.) If your equipment is X series, first you should close USB to COM serve, open Control Panel> Tools> Services, find "Bulk to Serial service", select properties: select stop, Startup Type: Manual.

5. After installed the new driver, how to find out the COM port corresponding to the USB Com Port Emuation?
A. Open Start> all the procedures>vcomctrl>vcomctrl, you can find the number of the COM port there.

6. Why QuickSet can not connect the equipment through USB after installed v1.2 driver?
A. Confirm FAQ-1 driver has installed correctly --> Check out the number of COM port of FAQ-4 --> Confirmed equipment has been launched. Open the Quickset, select the right COM port,manual detection. If the detection failed, you can choose one of the following ways to solve the problem:

i.Check out whether swich to HID-KBW and have set Non-HID-KBW when read The Manual of Settings Code. Change and connect it again.

ii. If it connect through COM before, open "File>PC comm... > USB>OK" in Quickset, try whether it work.

iii. Close Quickset, close connection then open Control Panel> Tools> Services, find "Bulk to Serial service", select properties: select stop, and then start it again. Connect the equipment, open Quickset, try connection through COM.

iv. Close Quickset, close connection. Reboot the equipment, open Quickset, connect it again.






Cable

USB Cable 
Communication with PC 
Model:CBL024U

RS232 Cable 
Communication with PC 
Model:CBL037R

Ps2 Cable 
Communication with PC 
Model:CBL013P

Power
Adapter
For charge 
Model:KSAS0100500150D5
Base

Base
For charge and Communication with PC
Model:CD1500

  Iron Bracket
For fixing the cradle on the wall



NEWS

Newland President Ms. Wang Jing joined China-Germany Economic Advisory Committee CEO Roundtable
More »
Season II Overseas Exhibition Start Now
More »
Newland release the first 2D-barcode decoder chip on the world wide scale
More »
Newland and Datalogic sign the Cooperative Strategy Framework Agreement
In November 11th, Fujian Newland Computer Co., LTD. and Datalogic SpA.(Italy) formally sign the Cooperative Strategy Framework Agreement in Beijing International Hotel.

More »