Products

OEM Products


Product Information

Model: NLS-EM1365-LD
Product Category: 1D OEM scan engine
Data type: 1D Bar Codes
Reading Mode:
Linear Image
Interface: TTL-232, USB
Wireless: None


Overview
The NLS-EM1365-LD OEM scan engine, armed with linear imager, is suitable to be integrated into various OEM devices including kiosks, ticket validators and PDAs. The NLS-EM1365-LD’s core technology is independently developed by Newland, comprising optical system, digitizer, decoder, image processor and embedded system. The device demonstrates an unprecedented decoding capability on all mainstream 1D symbologies. The NLS-EM1365-LD supports EAN-13, EAN-8, UPC-A, UPC-E, ISSN, ISBN, Codabar, Code 128, Code 93, ITF-6, ITF-14, Interleaved 2 of 5, Industrial 2 of 5, Standard 2 of 5, Matrix 2 of 5, GS1 Databar, Code 39, Code 11, MSI-Plessey, Plessey.

Features

Two-In-One Design
  • Seamless integration of imager and decoder board makes the scan engine small, lightweight and easy for integration.

Superior performance
  • The NLS-EM1365-LD delivers fast and accurate reading of 1D barcodes.

 


Low power consumption

The scan engine provides an optimal solution for battery-operated equipments and mobile devices.


Easy to use

Simple parameter configuration.




Specification
<

Performance

Interface

TTL-232, USB1.1

Image Sensor

Linear imager

Resolution

1500

Scan Rate

300 scans per second

Symbologies

EAN-13, EAN-8, UPC-A, UPC-E, ISSN, ISBN, Codabar, Code 128, Code 93, ITF-6, ITF-14, Interleaved 2 of 5, Industrial 2 of 5, Standard 2 of 5, Matrix 2 of 5, GS1 Databar, Code 39, Code 11, MSI-Plessey, Plessey.

Reading Precision

≥ 4mil

Light Source

LED (610nm ~ 640nm)

Depth of Field*

Code 39 (5mil): 65mm~175mm
EAN-13 (13mil): 55mm ~ 605mm

Scan Angle**

Pitch

±60°@ 0°Roll and 0°Skew

Roll

±30°@ 0°Pitch and 0°Skew

Skew

±60°@ 0°Roll and 0°Pitch

Symbol Contrast

≥ 30% reflectance difference

Mechanical/Electrical

Rated Power Consumption

0.20W

Operating Voltage

3.0 ~ 3.6VDC

Current @ 3.3VDC

Operating Current

60mA

Standby Current

25mA

Dimensions

28.25(W)×21.99(D)×11.75(H)mm

Weight

6.0g

Environmental

 

Operating Temperature

-20°C ~ +60°C

Storage Temperature

-40°C ~ +85°C

Humidity

5% ~ 95% (non-condensing)

Ambient Light

0 ~ 100,000 LUX

Certifications

FCC Part15 Class B; CE EMC Class B

Accessories

NLS-EVK3000

Software development board, equipped with a trigger button, beeper and RS-232 & USB interfaces.

Cable

RS-232 Cable

Used to connect the NLS-EVK3000 to a host device; equipped with a power connector.

USB Cable

Used to connect the NLS-EVK3000 to a host device.

Power Adaptor

Used to provide power for the NLS-EVK3000.
Output: DC5V, 2A; Input: AC100~240V, 50~60Hz.

* Test conditions: T=23℃, Illumination=300 LUX
** Test conditions:
Code 39, 3 Bytes; Resolution=10mil; W:N=3:1; PCS=0.8; Barcode Height=11mm; Scan Distance=120mm, T=23℃, Illumination=300 LUX


**Test conditions:

Code 39, 3 Bytes; Resolution=10mil; W:N=2.5:1; PCS=0.8; Barcode Height=40mm; Scan Distance=210mm, T=23℃,  Illumination= 200 LUX


*Specifications are subject to change without notice*



  Document Name Size Document Type
1 NLS-EM1365-LD Datasheet 350K Datasheet
2 NLS-EM1365-LD User_Guide 2712K User_Guide
3 NLS-EM1365-LD Integration_Guide 562K Integration_Guide


1. How to confirm the types of your equipment, X+? X? or other type?
A. X+ type(EM2027 series, last number of serial number is "X+"), supported interface types: USB-DataPipe, USB Com Port Emuation, HID-KBW,RS232.
X type(EM2100 series,last number of serial Number is "X"), supported interface types: USB-DataPipe, USB Com Port Emuation, HID-KBW,RS232.

2. How to confirm whether the driver has been installed successfully?
A. First, confirm the equipment had connected to PC and the equipment operating normally.
Open: Control Panel> Device Manager> Universal Serial Bus Controller,
 If there is "Newland USB Datapipe to series Device" said connection is "USB Com Port Emuation"--COM.
 If there is "Newland USB DataPipe Device" said connection is "USB-DataPipe".
 If there is yellow "!" before the equipment, delete the equipment, and then scan detection hardware changes,  Wait for the system to automatically install the new drivers finished.

3. Whether it is necessary upgrade the driver of USB-Datapipe from the old version to the new v1.2 USB driver (vcomctrl v1.2.exe)?
A. The new driver support USB Interface of X+ : USB-DataPipe/ USB Com Port Emuation/HID-KBW. If the users of X series, had developed their own application through the USB SDK, recommendations are not updated to the latest driver.

4. If you have installed v1.2 USB driver, how to connect by USB-Datapipe?
A. If your equipment is X+ series, read the set code of USB-Datapipe.(You can download The Manual of Settings Code free from this website.) If your equipment is X series, first you should close USB to COM serve, open Control Panel> Tools> Services, find "Bulk to Serial service", select properties: select stop, Startup Type: Manual.

5. After installed the new driver, how to find out the COM port corresponding to the USB Com Port Emuation?
A. Open Start> all the procedures>vcomctrl>vcomctrl, you can find the number of the COM port there.

6. Why QuickSet can not connect the equipment through USB after installed v1.2 driver?
A. Confirm FAQ-1 driver has installed correctly --> Check out the number of COM port of FAQ-4 --> Confirmed equipment has been launched. Open the Quickset, select the right COM port,manual detection. If the detection failed, you can choose one of the following ways to solve the problem:

i.Check out whether swich to HID-KBW and have set Non-HID-KBW when read The Manual of Settings Code. Change and connect it again.

ii. If it connect through COM before, open "File>PC comm... > USB>OK" in Quickset, try whether it work.

iii. Close Quickset, close connection then open Control Panel> Tools> Services, find "Bulk to Serial service", select properties: select stop, and then start it again. Connect the equipment, open Quickset, try connection through COM.

iv. Close Quickset, close connection. Reboot the equipment, open Quickset, connect it again.



  Document Name Size Document Type
1 signed_driver for 1D_chip.zip 6K Driver



NEWS

Newland President Ms. Wang Jing joined China-Germany Economic Advisory Committee CEO Roundtable
More »
Season II Overseas Exhibition Start Now
More »
Newland release the first 2D-barcode decoder chip on the world wide scale
More »
Newland and Datalogic sign the Cooperative Strategy Framework Agreement
In November 11th, Fujian Newland Computer Co., LTD. and Datalogic SpA.(Italy) formally sign the Cooperative Strategy Framework Agreement in Beijing International Hotel.

More »