Products

OEM Products


Product Information

Model: NLS-EM3090
Product Category: 2D Barcode Scanning Engine
Data type: 2D Bar Codes
Reading Mode:
CMOS
Interface: TTL-232, USB
Wireless: None


Features

Technology

Newland’s sixth-generation  technology gives the scan engine an edge with unrivaled decoding capabilities on 1D & 2D barcodes.


Superior 1D Barcode Reading Performance

Optimized for reading 1D barcodes, the NLS-EM3090 can decode high-volume 1D barcodes and those of poor quality effortlessly.


Multiple Interfaces

The NLS-EM3090 supports USB and TTL-232 interfaces to meet diverse customer needs.


Compact & Lightweight Design

Seamless integration of imager and decoder board makes the scan engine extremely small and lightweight and easy to fit into space-constrained equipment.


Outstanding Power Efficiency

The advanced     technology incorporated in the scan engine helps reduce the power consumption and prolong the service life of the device.




Specification

Performance

Image Sensor

752×480 CMOS

Light Source

Red LED 625±10 nm

Symbologies

2D          PDF417, QR Code (QR1/2, Micro), Data Matrix (ECC200, ECC000, 050, 080, 100, 140), Chinese Sensible Code

1D          Code128, UCC/EAN-128, AIM128, EAN-8, EAN-13, ISBN/ISSN, UPC-E, UPC-A, Interleaved 2 of 5, ITF-6, ITF-4, Matrix 2 of 5, Industrial 25, Standard 25, Code 39, Codabar, Code 93, Code 11, Plessey, MSI-Plessey, GS1-DataBarTM(RSS), (RSS-14, RSS-Limited, RSS-Expand)

Resolution

≥5mil

Typical Depth of Field

EAN-13      50mm-445mm (13mil)

PDF417      70mm-160mm (6.67mil)

Code 39     50mm-215mm (5mil)

Data Matrix  60mm-150mm (10mil)

QR Code     35mm-210mm (15mil)

Symbol Contrast

≥25% reflectance difference

Scan Angle**

Roll: 360°,  Pitch: ±55°,  Skew: ±55°

Field of View

Horizontal 36°,  Vertical 23°

Mechanical/
Electrical

Interface

TTL-232, USB (HID-KBW, COM Port Emulation, HID-POS)

Operating Voltage

3.0~3.6VDC

Current@3.3VDC

Operating   190mA

Standby     7mA

Sleep       <5uA

Dimensions

28.0(W)×24.5(D)×13.9(H)mm

Weight

9.5g

Environmental

Operating Temperature

-20℃~+55℃(-4°F~131°F)

Storage Temperature

-40℃~+80℃(-40°F~176°F)

Humidity

5%~95% (non-condensing)

Ambient Light

0~100000lux (natural light)

Accessories

NLS-EVK3000

Software development board for the NLS-EM3090, equipped with a trigger button, beeper and RS-232 & USB interfaces.

Cable

USB         Used to connect the NLS-EVK3000 to a host device.
RS-232      Used to connect the NLS-EVK3000 to a host device.

Power Adaptor

Used toprovide power for the NLS-EVK3000.
Output: DC5V, 2A;   Input: AC100~240V, 50~60Hz

**Test conditions:

Code 39, 3 Bytes; Resolution=10mil; W:N=2.5:1; PCS=0.8; Barcode Height=40mm; Scan Distance=210mm, T=23℃,  Illumination= 200 LUX


*Specifications are subject to change without notice*



  Document Name Size Document Type
1 NLS-EM3090 Datasheet 297K Datasheet
2 NLS-EM3090 User_Guide 715K User_Guide
3 NLS-EM3090 Integration_Guide 1740K Integration_Guide


1. How to confirm the types of your equipment, X+? X? or other type?
A. X+ type(EM2027 series, last number of serial number is "X+"), supported interface types: USB-DataPipe, USB Com Port Emuation, HID-KBW,RS232.
X type(EM2100 series,last number of serial Number is "X"), supported interface types: USB-DataPipe, USB Com Port Emuation, HID-KBW,RS232.

2. How to confirm whether the driver has been installed successfully?
A. First, confirm the equipment had connected to PC and the equipment operating normally.
Open: Control Panel> Device Manager> Universal Serial Bus Controller,
 If there is "Newland USB Datapipe to series Device" said connection is "USB Com Port Emuation"--COM.
 If there is "Newland USB DataPipe Device" said connection is "USB-DataPipe".
 If there is yellow "!" before the equipment, delete the equipment, and then scan detection hardware changes,  Wait for the system to automatically install the new drivers finished.

3. Whether it is necessary upgrade the driver of USB-Datapipe from the old version to the new v1.2 USB driver (vcomctrl v1.2.exe)?
A. The new driver support USB Interface of X+ : USB-DataPipe/ USB Com Port Emuation/HID-KBW. If the users of X series, had developed their own application through the USB SDK, recommendations are not updated to the latest driver.

4. If you have installed v1.2 USB driver, how to connect by USB-Datapipe?
A. If your equipment is X+ series, read the set code of USB-Datapipe.(You can download The Manual of Settings Code free from this website.) If your equipment is X series, first you should close USB to COM serve, open Control Panel> Tools> Services, find "Bulk to Serial service", select properties: select stop, Startup Type: Manual.

5. After installed the new driver, how to find out the COM port corresponding to the USB Com Port Emuation?
A. Open Start> all the procedures>vcomctrl>vcomctrl, you can find the number of the COM port there.

6. Why QuickSet can not connect the equipment through USB after installed v1.2 driver?
A. Confirm FAQ-1 driver has installed correctly --> Check out the number of COM port of FAQ-4 --> Confirmed equipment has been launched. Open the Quickset, select the right COM port,manual detection. If the detection failed, you can choose one of the following ways to solve the problem:

i.Check out whether swich to HID-KBW and have set Non-HID-KBW when read The Manual of Settings Code. Change and connect it again.

ii. If it connect through COM before, open "File>PC comm... > USB>OK" in Quickset, try whether it work.

iii. Close Quickset, close connection then open Control Panel> Tools> Services, find "Bulk to Serial service", select properties: select stop, and then start it again. Connect the equipment, open Quickset, try connection through COM.

iv. Close Quickset, close connection. Reboot the equipment, open Quickset, connect it again.



  Document Name Size Document Type
1 signed_driver for 2D_chip_MCU.zip 7K Driver



NEWS

Newland President Ms. Wang Jing joined China-Germany Economic Advisory Committee CEO Roundtable
More »
Season II Overseas Exhibition Start Now
More »
Newland release the first 2D-barcode decoder chip on the world wide scale
More »
Newland and Datalogic sign the Cooperative Strategy Framework Agreement
In November 11th, Fujian Newland Computer Co., LTD. and Datalogic SpA.(Italy) formally sign the Cooperative Strategy Framework Agreement in Beijing International Hotel.

More »